Operation condition – Инструкция по эксплуатации Panasonic CS-E9

Страница 3

Advertising
background image

ENGLISH

3

OPERATION CONDITION

OPERATION CONDITION

Use this air conditioner under the following temperature range

Single Split Outdoor Unit

(CU-E7NKD, CU-E9NKD, CU-E12NKD, CU-E15NKD, CU-E18NKD)

Temperature (°C)

Indoor

Outdoor

*DBT

*WBT

*DBT

*WBT

COOLING

Max.

32

23

43

26

Min.

16

11

16

11

HEATING

Max.

30

-

24

18

Min.

16

-

-5

-6

Multi Split Outdoor Unit

Temperature (°C)

Indoor

Outdoor

Outdoor

U-2E15GBE, U-2E18CBPG

U-3E18JBE, U-4E23JBE

*DBT

*WBT

*DBT

*WBT

*DBT

*WBT

COOLING

Max.

32

23

43

26

46

26

Min.

16

11

16

11

-10

-

HEATING

Max.

30

-

24

18

24

18

Min.

16

-

-10

-11

-15

-16

* DBT: Dry bulb temperature
* WBT: Wet bulb temperature

Advertising
Эта инструкция подходит к следующим моделям: