Switch 2: Parity Check

This switch specifies whether or not a parity check should be performed
on the data.

Parity Check

SW2

DOS Setting

Disabled

ON

Disabled

Enabled

OFF

Enabled

Switch 3: Parity

This switch specifies the parity as non, odd, or even.

Parity

SW3

DOS Setting

Odd

ON

O

Even

OFF

E

Switch 4: Protocol

Protocol, which is sometimes referred to as “handshaking,” is the com-
munications convention that is used to allow the printer and computer
to regulated the flow of data. DTR is the most commonly used proto-
col.

Protocol

SW4

DOS Setting

DTR

ON

DTR

XON/XOFF

OFF

XON/XOFF

Switches 5, 6: Not used

BANK B

Switch 1, 2, 3: Baud Rate

The baud rate is the speed, in bits per second, that the printer sends
data to the computer. The common setting is 9600 or 19200.