Installation, En 5 5, 3 - installation – Инструкция по эксплуатации Smeg KSEG51

Страница 5

Advertising
background image

EN

5

5

INSTALLATION

3 - INSTALLATION

The following scheme has to be observed:

3.1 - Installation of the built-in group

3.2 - Set the hood for recirculation or evacuation

3.2 - Connect the hood to the mains supply and ensure that it works properly


3.1 - Installation of the fitted group
1 - Make a rectangular opening in the base of the overhead cupboard or hood, leaving a minimum

of 13 mm from the outer edges according to the dimensions indicated in the table.

2 - Drill a hole into the upper side of the cabinet in accordance with the dimensions of the duct

used for both the evacuation and recirculation mode.

3 - Dismantle the ducting support (version with grill or version with filters), pulling the two pom-

mels A (fig. 1) simultaneously:

a) Fixing frame with screws:

Fix the fitted group to the hood or cupboard, using the self-threading screws (No. 8) pro-

vided with the accessories (fig. 2).

b) Rapid fixing with side supports:

The device B is set up to deal with a panel thickness of from 15 mm to 30 mm. Insert the

group into the opening until the two devices B connect. Lock the adjustment screw C until
the fitted group adheres tightly to the surface (fig. 2).

4 - Close the ducting support by pushing and connecting the two pommels A (fig. 3).
3.2 - Ducting or recirculation fitting
1 - Ducting fitting:

a - The hood can be ducted to the outside using either a rigid or a flexible Ø 100 or 120 mm

duct to be fixed with suitable clamps, not provided (fig. 2).

b - If the hood is provided with the charcoal filters fitted, the filters should be removed (see

par.6.2).

2 - Recirculation fitting:

a - When used in the recirculation mode, the charcoal filters must be fitted into the cooker

hood (see par. 6.2).

b - The air is recirculated into the kitchen through the opening located on the upper side of the

cabinet or of the hood (fig. 3).

3.3 - Electrical connection and working test
1 - The safety measures 4.2, 4.3 and 4.4.
2 - Once the electrical connection has been completed, check that the worktop illumination, motor

and speeds work properly.

520 mm

700 mm

Side A

497 mm

677 mm

Side B

259 mm

259 mm

Cooker Hood

Dimensions